Enquiries answered within 5 hours

16S6P battery case — 96 cells, 60 V

A 16S6P pack is 96 cells: 16 groups in series, 6 in parallel in each group. This page lists the 18650 housings that actually take it, in the order of how much room they leave for the BMS and the wiring.

Short answer: 19 of our 110 housings take a 16S6P on 18650. 15 of those leave at least six cells of room — which is the practical minimum once a 16S BMS and the wiring are in.

The pack, in numbers

Cells96
Nominal voltage16 × 3.6 V = 60 V
Charge voltage16 × 4.2 V = 67.2 V
Capacity (typical)6 × 3.5 Ah = 21.0 Ah
Energy (typical)1210 Wh

Capacity assumes 3.5 Ah per 18650 cell. Your cells will differ — the cell count and the voltage are exact, the capacity is a working figure.

Housings that take it

Model18650 ceilingRoom left
ALX038 · Silver Fish1004
ALX042B · Silver Fish1004
ALX072 · Silver Fish1004
ALX072B · Silver Fish1004
ALX050 · Silver Fish1048
ALX051 · Silver Fish1048
ALX057 · Silver Fish1048
ALX110B · Integrated1048
ALX127 · Downtube1048
ALX149A · Hailong1048
ALX166A · Rear Rack1048
ALX166B · Rear Rack1048
ALX139 · Downtube10812
ALX149B · Hailong11721

Showing the 14 with the most room. The other 5 are in the case selector.

Why room left matters more than the ceiling. A housing listed at 96 cells holds your pack exactly and nothing else — no BMS, no nickel, no cable exit. In practice a 16S pack needs roughly six cells of space beyond the cells themselves, because a 16S BMS is longer than the 10S board these moulds were designed around. That is the single most common reason a build that “fits” does not close. There is a longer explanation in why your 13S5P pack will not fit.

Work out your own configuration

The pack calculator does this for any series and parallel count, and the case selector takes a plain cell count if you already know it.

What 1210 Wh actually gets you

The figure above is energy, not distance. A 16S6P pack on 18650 works out to about 1210 Wh, which is roughly 101–151 km on low assist and 38–55 km at full assist for a 75 kg rider on mixed terrain. How far a pack will take you explains what moves that figure, and how the same configuration on the other cell format compares.

Other configurations

The parallel count is what changes the housing, not the series count.

Common questions

How many cells is a 16S6P pack?
96 cells — 16 groups wired in series, 6 cells in parallel in each group.
What voltage is 16S?
60 V nominal (16 x 3.6 V), charging to 67.2 V.
Which battery case takes a 16S6P pack on 18650?
19 of our housings take it. 15 leave at least six cells of room for the BMS and wiring.
Can I use a 16S6P pack in a case listed at fewer cells?
No. The listing is the ceiling. If a housing says it takes 93 cells it will not take 96.

Send us the pack and we will confirm the fit

Cell format, series and parallel count is usually enough to answer the same day. If the answer is that none of our moulds fit, we will say so.