Find an e-bike battery case by cell count
Short answer: tell us 18650 or 21700 and the number of cells, and this lists every housing in production that takes them. On 18650 the range runs from 14 to 130 cells (143 models); on 21700 from 14 to 100 (86 models). Every case is an empty shell — no cells, no BMS.
Cell-count bands, with the models that hit them
18650 143 models
| Ceiling (cells) | Models | Examples |
|---|---|---|
| 14 | 1 | ALX310 |
| 30 | 9 | ALX095 · ALX105 · ALX218 · ALX225 |
| 40 | 22 | ALX003 · ALX011 · ALX014 · ALX216 |
| 50 | 2 | ALX069 · ALX283 |
| 52 | 29 | ALX006 · ALX019A · ALX029 · ALX054 |
| 60 | 12 | ALX032 · ALX200 · ALX202 · ALX210 |
| 65 | 26 | ALX030 · ALX030B · ALX030D · ALX035 |
| 75 | 1 | ALX009 |
| 78 | 15 | ALX100 · ALX019B · ALX053B · ALX053C |
| 80 | 2 | ALX323 · ALX324 |
| 90 | 2 | ALX230 · ALX231 |
| 91 | 2 | ALX082 · ALX212 |
| 100 | 1 | ALX284 |
| 103 | 1 | ALX325 |
| 104 | 11 | ALX038 · ALX042B · ALX050 · ALX057 |
| 112 | 2 | ALX320 · ALX326 |
| 117 | 1 | ALX149B |
| 130 | 4 | ALX021 · ALX036 · ALX061 · ALX063 |
21700 86 models
| Ceiling (cells) | Models | Examples |
|---|---|---|
| 14 | 1 | ALX311 |
| 20 | 9 | ALX105 · ALX285 · ALX287 · ALX076 |
| 26 | 5 | ALX006 · ALX029 · ALX107 · ALX124 |
| 28 | 1 | ALX058 |
| 30 | 2 | ALX068 · ALX096 |
| 39 | 1 | ALX080 |
| 40 | 22 | ALX009 · ALX030 · ALX030B · ALX030D |
| 42 | 1 | ALX243 |
| 43 | 1 | ALX060B |
| 46 | 1 | ALX119A |
| 50 | 1 | ALX265 |
| 52 | 22 | ALX082 · ALX019B · ALX077B · ALX097 |
| 54 | 2 | ALX323 · ALX324 |
| 56 | 1 | ALX108B |
| 65 | 2 | ALX127 · ALX325 |
| 69 | 1 | ALX050 |
| 70 | 1 | ALX149A |
| 78 | 2 | ALX166B · ALX240 |
| 80 | 5 | ALX149B · ALX166A · ALX284 · ALX100 |
| 84 | 2 | ALX320 · ALX326 |
| 91 | 2 | ALX061 · ALX063 |
| 100 | 1 | ALX149D |
“Ceiling” is the largest pack the mould takes, taken from the live catalogue. A model appears under the band it tops out at, not at every count below it.
Questions this answers
How many cells does a battery case hold?
On 18650 cells the range runs from 14 to 130 cells, and on 21700 from 14 to 100. The ceiling is set by the mould, not the BMS: a case sold as a 52-cell shell physically holds 52 18650 or about 42 of the larger 21700.
Should I choose by cell count or by opening length?
Cell count first — it is published for every model in production. Opening length is only measured on the models that have a drawing, so using it as the first filter hides otherwise suitable cases.
Can I fit fewer cells than the ceiling?
Yes. The ceiling is a maximum, not a requirement; a 78-cell case with a 52-cell pack needs a spacer or a holder block, which is normal practice in pack assembly.