Enquiries answered within 5 hours

Frame tube to battery box — what a 121 × 65 mm tube actually holds

Short answer: a frame tube tells you the size of the housing that goes inside it, not how many cells that housing holds. On 13 of the 14 in-frame moulds where we hold both a tube size and a box section, the box runs 6.6–7.0 mm smaller than the tube in both axes — a 121 × 65 mm tube takes a 114.2 × 58 mm box. The cell count belongs to the individual mould.

Short answer: a frame tube tells you the size of the housing that goes inside it, not how many cells that housing holds. On 13 of the 14 in-frame moulds where we hold both a tube size and a box section, the box runs 6.6–7.0 mm smaller than the tube in both axes — a 121 × 65 mm tube takes a 114.2 × 58 mm box. The cell count belongs to the individual mould.

The number that transfers: 7 mm

The tube figure is the outside of the frame. The pack sits in the box: the section that carries the cells, the board and the foam. Between the two sit the wall of the housing, its finish, the seal and the clearance the box needs to slide in. Across our records that stack measures 6.6–7.0 mm of width and 6.8–7.0 mm of height, which is 3.3–3.5 mm per side.

13 of 14 records land inside that band, and they span tubes from 47 mm to 74.8 mm, so it comes from how the section is built rather than from one mould. It also runs in the useful direction: pick the box you want, add 7 mm to each axis, and that is the tube to leave.

Frame tube (W × H)Battery box (W × H)18650 cells 21700 cellsModels
90 × 53.0764.83 × 43.720 · 30—ALX095
94.8 × 4788 × 4030 · 40—ALX011 · ALX014
100 × 66.893.4 × 605240ALX079 · ALX084
109 × 50102.2 × 4340 · 50 · 5226ALX107 · ALX124
109 × 67102.2 × 60.240 · 50 · 52 · 6526ALX006 · ALX056 · ALX060
117 × 74.8110 × 67.865 · 7852ALX106 · ALX108 · ALX131
121 × 65114.2 × 587540ALX009

14 of the 21 in-frame models carry a tube size in our records, and they resolve to 7 sections. The rest carry no tube figure, so none is inferred here.

The cell columns are the counts each model is tooled for — an orderable menu, not a computed maximum. Where two models share a section, both menus are listed. A 21700 is 21 mm across against 18.4 mm for an 18650, so the same box holds fewer of them; a dash means the model is not offered on 21700 at all, not that the figure is missing.

The drop is not one number. On the 102.2 × 60.2 box the menu runs 52 cells of 18650 and 26 of 21700. On the 93.4 × 60 box it runs 52 and 40. Both sections belong to the same range, and the second gives up far less. That is the reason to read the menu per model instead of applying a factor.

Same tube, different cell count

ALX006, ALX056 and ALX060 are cut for the same 109 × 67 mm tube and the same 102.2 × 60.2 mm box. Their menus are not the same:

ModelFrame tubeBattery box1865021700
ALX006109 × 67102.2 × 60.240 · 50 · 5226
ALX056109 × 67102.2 × 60.252 · 65—
ALX060109 × 67102.2 × 60.252 · 65—

What differs is inside — where the board sits, how the cells are held, how much the end caps take. None of that shows in a section drawing. So "what fits in a 109 × 67 frame" has no single answer, and a supplier who quotes a cell count from a tube size is guessing at the part that decides it.

The widest box is not the biggest

The widest box in the table is 114.2 mm, cut for a 121 × 65 tube, and it takes 75 cells of 18650. A narrower 110 mm box takes 78, on a 370 mm tube against 345 mm. Width sets how many cells sit across; length sets how many rows of them; height sets how many layers. The wide, short housing loses to the narrower, longer one, and nothing in the section drawing says so.

Where the rule breaks

ALX095's tube measures 90 × 53.07 mm and its box 64.83 × 43.7 — 25.2 mm narrower than the tube, not 7. That gap is far too large for wall thickness, so something else occupies the width: an insert, a door, a different construction. The record does not say which and it is not worth guessing at. What it does say is that 7 mm is a majority rule, not a law.

The practical version: ask for the box section, not the tube. A supplier who can send a section view is working from a mould. One who answers with the frame's tube size is telling you what he can see, not what he can make.

Designing the frame the other way round

Backwards, the same arithmetic becomes a constraint. To run the 110 × 67.8 box you need a tube of at least 117 × 74.8 mm. The tube gets welded before the housing is ordered and cannot be widened afterwards; the housing can be re-cut, re-capped or re-moulded. If the frame is still on paper, settle the box with the housing supplier first and weld the tube to it.

What to send

  • Tube section, measured inside, at the widest point and again 30 mm from the weld. The narrowest reading is the one that decides.
  • Tube length along the box, after the battery door and any insert.
  • Whether the frame has a door, an insert or a bolted panel inside the tube. An insert is what turns a 7 mm gap into a 25 mm one.
  • Cell format, the cell count you need, and the board. The section caps how many cells sit side by side; the board and the end caps take the rest of the length.

Every model with a published opening is on the measured size table, and the in-frame range with sections and lengths is the Integrated & In-Frame series. If the frame is still being designed, the four numbers to fix with the housing supplier are in what internal dimensions to ask for, and where those numbers sit on a mould drawing is in how to read a case drawing.

Common questions

My frame tube is 121 × 65 mm. Which housing fits inside it?
A 114.2 × 58 mm box - on our moulds the housing box runs 6.6-7.0 mm under the tube in both axes. ALX009 is the model cut for that tube: 75 cells of 18650, or 40 of 21700.
Can I work out the cell count from the frame tube size?
No. ALX006, ALX056 and ALX060 take the same 109 × 67 tube and the same 102.2 × 60.2 box but are tooled for different counts (52 against 65 on 18650). The count belongs to the model.
How much clearance does a frame need to leave for an in-frame housing?
On our moulds the box is 6.6-7.0 mm smaller than the tube on each axis, about 3.3-3.5 mm per side, which covers wall thickness, finish and sliding clearance. Confirm the figure against the housing supplier's own section drawing - it is a property of the housing, not a standard.
Why does a 90 × 53.07 mm tube hold fewer cells than a 94.8 × 47 mm one?
Because the boxes differ far more than the tubes: 64.83 × 43.7 mm against 88 × 40 mm. 25.2 mm of the wider tube's width goes to something other than the box, far more than wall thickness, so the tube size overstates what is inside. Compare the box, not the tube.

Send us the pack and we will confirm the fit

Cell type, series and parallel count is usually enough. If the answer is that none of our moulds fit, we will say so rather than sell you the nearest thing.